Jitter Measured on HB Backplane

CCM provides clock via TTCrx clock cleaned up with RoboClockII

SLOT

1

2

3

4

5

6

7

8

13

14

15

16

17

18

Clock Period jitter RMS (ps)

10

10

10

10

9

10

9

9

9

9

9

9

9

9

Cycle to cycle jitter RMS (ps)

14

14

14

13

13

14

13

13

12

12

12

12

13

13

 

CCM provides clock via Oscillator cleaned up with RoboClockII

SLOT

1

2

3

4

5

6

7

8

13

14

15

16

17

18

Clock Period jitter RMS (ps)

10

9

10

10

9

9

9

9

10

9

9

9

9

9

Cycle to cycle jitter RMS (ps)

13

13

13

14

13

13

13

13

13

13

13

13

13

13

 

CCM provides clock via TTCrx clock cleaned up with QPLL

SLOT

1

2

3

4

5

6

7

8

13

14

15

16

17

18

Clock Period jitter RMS (ps)

21

20

23

23

21

23

15

21

25

17

20

24

22

22

Cycle to cycle jitter RMS (ps)

39

36

43

43

40

43

26

36

47

30

36

44

40

42


Jitter Measured on HO Backplane

CCM provides clock via TTCrx clock cleaned up with RoboClockII

SLOT

1

2

3

4

5

6

7

8

13

14

15

16

17

18

Clock Period jitter RMS (ps)

9

9

9

9

9

9

8

9

8

9

9

8

9

9

Cycle to cycle jitter RMS (ps)

12

12

12

12

12

12

11

12

12

12

11

11

11

11

 

  